Software
Designed and documented in the technical docs; nothing is released yet.
Status
| Item | Status |
|---|---|
| Motor firmware | Not released |
| Object dictionary (device description file, EDS/XDD) | Not released |
| ROS 2 driver | Not released |
| Firmware updater | Not released |
| Host software | Standard open tools; Draft (technical docs) |
| Test-method data logger | Planned |
| Thermal model | Planned |
Statuses we’ll use: Released, Draft, Not released, Planned, TBD.
Interface principles
- Bus: CAN FD, with classic CAN at 1 Mbit/s (design value).
- Motion: designed for CANopen (CiA 402); not released.
- Diagnostics, settings, updates: designed for UDS (ISO 14229) over ISO-TP (ISO 15765-2); not released.
- Signed firmware images: designed, not built.
Technical documentation
Reference documentation for a drive in development. It describes the design; nothing in it is built, released or measured.
Start
Getting started
Bench set-up, tools to install and first contact over CAN, written ahead of firmware release.
Draft
Hardware
Mechanical integration
Envelope, mounting to frame and output link, and the clear bore. Design values for prototype hardware; they will change.
DraftElectrical and CAN wiring
48 V supply, returned energy, bus wiring and termination. Connector and pin-out are TBD.
Draft
Host software
CAN FD on Linux (SocketCAN)
Set up and check a CAN FD interface on Linux with SocketCAN, can-utils and python-can.
DraftCANopen (CiA 402)
Planned object dictionary, state machine, modes and PDOs. Not released.
DraftUDS diagnostics
Planned identity, sessions and fault codes over ISO-TP. Identifiers are TBD.
Draft
Operation
Configuration
Planned settings, node ID and bit rate, changed over CANopen or UDS.
DraftCalibration
How calibration data is planned to be stored and backed up.
DraftFirmware updates
Planned update sequence over UDS. No firmware is released.
Draft
Safety
Safety
Protective functions as designed. Safe torque off is designed, not certified.
DraftInterlock loop (HVIL)
What the planned interlock loop (HVIL) is for, its wiring and bench tests. Timing is TBD.
Draft
Help
Troubleshooting
Symptoms, causes and checks for interface, bus, CANopen, UDS and updates.
Draft
The technical docs use standard open tools: can-utils, python-can, python-canopen, can-isotp, udsoncan.
sudo apt install can-utils
pip install python-can canopen can-isotp udsoncan
Resources
| Item | Status |
|---|---|
| Device description file (EDS/XDD) | Not released |
| ROS 2 driver | Not released |
| Firmware updater | Not released |
| Mounting drawing / STEP | TBD |
| Datasheet | Planned (measured figures only) |
Source code
No public repositories yet.
ROS 2 driver
The link appears here once the repository is public.
Not public yetFirmware updater
The link appears here once the repository is public.
Not public yetHost examples
The link appears here once the repository is public.
Not public yet
Gaps we see in the field
- Motor temperature. One 2026 study notes motor thermal management is often overlooked in legged robots (Wan et al., 2026).
- Bus security. The CAN protocol has no built-in message authentication.
- Simulation. Our reading of the literature we reviewed: common simulators don't model actuator heat by default.
What the joint should report
We plan for the joint to report what it knows to the robot. It should report:
| Field | Unit | Note |
|---|---|---|
| Mode / state | TBD | |
| Fault code | TBD | |
| Position | TBD | |
| Velocity | TBD | |
| Torque estimate | TBD | From motor current, not measured. |
| Motor temperature | TBD | Where it’s sensed will be stated. |
| Driver temperature | TBD | |
| Bus voltage | TBD | |
| Thermal headroom | TBD | How much continuous load remains before limits. |
| Firmware version | TBD | |
| Object dictionary version | TBD | |
| Timestamp | TBD |
Control rates and buses in the field
In one published research humanoid, the learned policy runs at 50 Hz while the joint PD controller runs at 25 kHz (Liao et al., 2024).
One open vision-language-action model predicts end-effector actions, not joint torques, and runs at about 6 Hz on one consumer GPU (Kim et al., 2024).
Classic CAN carries up to 8 data bytes per frame at up to 1 Mbit/s; CAN FD carries up to 64 bytes, with a faster data phase of several Mbit/s (both defined in ISO 11898-1). EtherCAT runs over 100 Mbit/s Ethernet (standardised in IEC 61158).
Test tooling
Planned: a data logger whose output will match the reporting template in our open test method.
Changelog
No releases yet.