Apsis Motion Labs Subscribe

A hollow-centre axial-flux motor for humanoid joints

A flat, ring-shaped axial-flux motor with an open centre that turns the joint directly, with no gearbox. Interface design values are in the technical docs; nothing is measured yet.

Design target, not measured Direct drive, no gearbox · 48 V DC nominal · CAN FD; classic CAN at 1 Mbit/s · Ø224 mm × 32 mm or Ø246 mm × 32 mm · clear bore Ø159.2 mm

Stage: prototype in development. No firmware released.

The concept

  1. Flat Short along the axis, for the short, wide space inside many joints.
  2. Room to build around Turns the output link directly, with no gearbox, and leaves room for an encoder and wiring.
  3. Open centre Left open for cables and sensor lines.
  4. Cable path Cables and sensor lines run through the open centre.
Illustrative model, not the actual drive. Not measured data.

Cables through the centre still twist as the joint turns; an open core gives them a shorter, protected path.

At a glance

ItemValueStatus
DriveDirect drive, no gearboxDesign target, not measured
Supply48 V DC nominalDesign target, not measured
BusCAN FD; classic CAN at 1 Mbit/sDesign target, not measured
Motion controlDesigned for CANopen (CiA 402)Not released
Diagnostics, settings, updatesDesigned for UDS (ISO 14229) over ISO-TPNot released
ROS 2Driver plannedNot released
Envelope, smaller sizeØ224 mm × 32 mmDesign target, not measured
Envelope, larger sizeØ246 mm × 32 mmDesign target, not measured
Clear boreØ159.2 mmDesign target, not measured
Torque and speedTBDTBD
MassTo be measuredTBD

Values for prototype hardware in development; they will change. Full values in Technical docs (reference documentation for a drive in development).

How it mounts (design)

  1. Bolt the drive's rim to your frame.
  2. Bolt your output link to the drive's output face.
  3. Run cables through the clear bore.

Hole patterns and the procedure are in Technical docs: Mechanical integration.

Who it's for

Robotics engineers and actuator teams designing arms, hips, knees and other rotating joints who want cleaner routing in a compact package.

Fit by joint (our current view, before measurement)

JointOur viewWhy
HipLikely fitShort along the axis, direct drive, cables through the centre.
ShoulderLikely fitShort along the axis, direct drive, cables through the centre.
WaistLikely fitShort along the axis, direct drive, cables through the centre.
Knee, elbow, ankle, wristOpen questionDepends on the space available and the torque needed.
Hands and fingersNot a fit yetToo small for this drive.

Not a fit yet

If your joint sounds like a likely fit, contact us; Contact lists what to send.

How a joint fits together

A typical rotary joint stacks several parts along one axis, within the length and diameter the robot allows:

Wiring for the rest of the limb has to cross the joint. Routed around the outside, it adds bulk and bends with every movement; through a slip ring, it adds parts. An open centre gives that wiring a path along the axis, through the stack, as long as the other parts in the stack leave the same path clear.

What we'll measure

We publish design values, marked as such; performance figures only once measured. This table lists what we'll report and the conditions behind each figure.

ParameterStatusConditions we'll state
Continuous torqueTo be measuredAmbient temperature, cooling, supply voltage, temperature limit used.
Peak torqueTo be measuredHow long the peak is held, starting temperature, supply voltage.
Temperature riseTo be measuredDuty cycle, ambient, cooling, where temperature is sensed.
Back-drive torqueTo be measuredAt the output, speed.
Cogging torqueTo be measuredSpeed, how it's measured.
EfficiencyTo be measuredOperating point, supply voltage, temperature.
MassTo be measuredWhat's included.

No values until measured. Methods: open test method.

What we can tell you now, and not yet

Now

Not yet

Until we're ready to discuss them:

Design questions we're working on

Resources

Where we are

We're early. Apsis Motion Labs is developing its first drive, now at the prototype stage. We aren't shipping product. We publish design values, marked as such; performance figures only once measured.

We plan these stages, in this order; we don't give dates.

  1. Concept and design (done)
  2. Prototype (current stage)
  3. Bench measurements under our published method
  4. Samples for design partners

If you're building a joint this could fit, contact us; Contact lists what to send.

Tell us about your joint