A hollow-centre axial-flux motor for humanoid joints
A flat, ring-shaped axial-flux motor with an open centre that turns the joint directly, with no gearbox. Interface design values are in the technical docs; nothing is measured yet.
Design target, not measured Direct drive, no gearbox · 48 V DC nominal · CAN FD; classic CAN at 1 Mbit/s · Ø224 mm × 32 mm or Ø246 mm × 32 mm · clear bore Ø159.2 mm
Stage: prototype in development. No firmware released.
The concept
- Flat Short along the axis, for the short, wide space inside many joints.
- Room to build around Turns the output link directly, with no gearbox, and leaves room for an encoder and wiring.
- Open centre Left open for cables and sensor lines.
- Cable path Cables and sensor lines run through the open centre.
3D view isn't available here; the drawing shows the same concept.
Select a part to highlight it. Drag or use arrow keys to rotate.
Cables through the centre still twist as the joint turns; an open core gives them a shorter, protected path.
At a glance
| Item | Value | Status |
|---|---|---|
| Drive | Direct drive, no gearbox | Design target, not measured |
| Supply | 48 V DC nominal | Design target, not measured |
| Bus | CAN FD; classic CAN at 1 Mbit/s | Design target, not measured |
| Motion control | Designed for CANopen (CiA 402) | Not released |
| Diagnostics, settings, updates | Designed for UDS (ISO 14229) over ISO-TP | Not released |
| ROS 2 | Driver planned | Not released |
| Envelope, smaller size | Ø224 mm × 32 mm | Design target, not measured |
| Envelope, larger size | Ø246 mm × 32 mm | Design target, not measured |
| Clear bore | Ø159.2 mm | Design target, not measured |
| Torque and speed | TBD | TBD |
| Mass | To be measured | TBD |
Values for prototype hardware in development; they will change. Full values in Technical docs (reference documentation for a drive in development).
How it mounts (design)
- Bolt the drive's rim to your frame.
- Bolt your output link to the drive's output face.
- Run cables through the clear bore.
Hole patterns and the procedure are in Technical docs: Mechanical integration.
Who it's for
Robotics engineers and actuator teams designing arms, hips, knees and other rotating joints who want cleaner routing in a compact package.
Fit by joint (our current view, before measurement)
| Joint | Our view | Why |
|---|---|---|
| Hip | Likely fit | Short along the axis, direct drive, cables through the centre. |
| Shoulder | Likely fit | Short along the axis, direct drive, cables through the centre. |
| Waist | Likely fit | Short along the axis, direct drive, cables through the centre. |
| Knee, elbow, ankle, wrist | Open question | Depends on the space available and the torque needed. |
| Hands and fingers | Not a fit yet | Too small for this drive. |
Not a fit yet
- You need a datasheet, measured figures or samples now.
- Joints built around high-ratio gears, such as strain-wave, make different trade-offs; they aren't our focus.
If your joint sounds like a likely fit, contact us; Contact lists what to send.
How a joint fits together
A typical rotary joint stacks several parts along one axis, within the length and diameter the robot allows:
- a motor, which makes the torque;
- a gearbox, which trades speed for torque (the Apsis drive has none);
- bearings, which carry the loads;
- an encoder, which measures angle;
- drive electronics, which control the motor current;
- wiring, for the joint itself and for everything further along the limb.
Wiring for the rest of the limb has to cross the joint. Routed around the outside, it adds bulk and bends with every movement; through a slip ring, it adds parts. An open centre gives that wiring a path along the axis, through the stack, as long as the other parts in the stack leave the same path clear.
What we'll measure
We publish design values, marked as such; performance figures only once measured. This table lists what we'll report and the conditions behind each figure.
| Parameter | Status | Conditions we'll state |
|---|---|---|
| Continuous torque | To be measured | Ambient temperature, cooling, supply voltage, temperature limit used. |
| Peak torque | To be measured | How long the peak is held, starting temperature, supply voltage. |
| Temperature rise | To be measured | Duty cycle, ambient, cooling, where temperature is sensed. |
| Back-drive torque | To be measured | At the output, speed. |
| Cogging torque | To be measured | Speed, how it's measured. |
| Efficiency | To be measured | Operating point, supply voltage, temperature. |
| Mass | To be measured | What's included. |
No values until measured. Methods: open test method.
What we can tell you now, and not yet
Now
- How we'll report torque: continuous torque separately from peak, with the conditions behind each figure.
- Our thermal test method, in the open test method.
- That back-drivability depends on the whole actuator, not the motor alone.
- The envelope and clear bore as design values (At a glance).
- What the open centre is for: cables and sensor lines along the axis.
- Our interface design: CAN FD, CANopen (CiA 402) and UDS, on the Software page.
- That we have no reliability data yet.
- Our stage, described under Where we are.
Not yet
Until we're ready to discuss them:
- Load and torque ratings.
- Prices.
- Availability and lead times.
Design questions we're working on
- Heat under real duty cycles. How a joint motor heats up over the load patterns a humanoid works through, not just in short bursts.
- Cable life through a rotating centre. How cables through the centre hold up as the joint turns back and forth.
- Measuring continuous torque honestly. Which conditions have to be stated for a continuous torque figure to mean something.
- What a joint should report to the robot. Which measurements, such as temperature and thermal headroom, the controller needs from the joint.
Resources
Datasheet
No files yet.
PlannedMounting drawing
No files yet.
PlannedTest report
No files yet. Reliability data comes after testing; we have none yet.
PlannedTechnical docs
Interface and integration guides, in draft.
DraftRepositories
No public repositories yet.
Not public yet
Where we are
We're early. Apsis Motion Labs is developing its first drive, now at the prototype stage. We aren't shipping product. We publish design values, marked as such; performance figures only once measured.
We plan these stages, in this order; we don't give dates.
- Concept and design (done)
- Prototype (current stage)
- Bench measurements under our published method
- Samples for design partners
If you're building a joint this could fit, contact us; Contact lists what to send.