Apsis Motion Labs Subscribe
GitHub · coming soon

Docs

Nothing released yet.

Choosing a joint motor

Axial vs radial flux in short spaces

Axial-flux machines are short along the axis and wide across it; radial-flux machines tend to be long and narrow. Where a joint is limited by its length along the axis, that shape matters. Published scaling laws for axial-flux motors come from in-wheel electric vehicle drives, not robot joints (Borsboom et al., 2024), so we treat them as a guide rather than a rule for joints.

What an open centre enables and costs

An open centre lets cables and sensor lines run along the axis, instead of around the outside of the joint or through slip rings. The centre of a motor contributes relatively little torque, so leaving it open gives up relatively little.

Our engineering view: it has costs too, including larger bearings and a different encoder choice.

Back-drivability is a property of the whole actuator

A motor on its own doesn't make a joint back-drivable. Reflected inertia grows with the square of the gear ratio, and gearbox friction adds to the torque needed to turn the joint from the output side. More torque from the motor allows a lower ratio, which keeps both down (Seok et al., 2014; Wensing et al., 2017).

Questions to ask any motor supplier, ours included

Continuous limits matter because heat sets them (Wan et al., 2026), and low torque density has size, weight and heat costs (Davis et al., 2026).

Glossary

Terms used on this site, in plain language.

Axial-flux motor
A flat motor in which the magnetic flux runs parallel to the shaft. It is short along the axis and wide across it.
Radial-flux motor
The conventional motor layout, in which the flux crosses the gap between the rotating and fixed parts in the radial direction. It tends to be long and narrow.
Back-drivability
How easily a load can turn the joint, and the motor behind it, from the output side. A back-drivable joint gives way to contact instead of resisting it.
Reflected inertia
The motor's rotating inertia as felt at the joint output. It grows with the square of the gear ratio.
Gear ratio
How many turns of the motor make one turn of the output. Torque is multiplied by the ratio, and reflected inertia by its square.
Direct drive
A motor that turns the joint output with no gearbox.
Quasi-direct drive
A high-torque motor paired with a low-ratio gearbox. It keeps reflected inertia low, so the joint stays back-drivable.
Planetary gear
A gear train with a central sun gear, planet gears around it and an outer ring. Robust and efficient, and common at low ratios in legged robots.
Strain-wave gear
A compact gear that reaches a high ratio by flexing a thin toothed ring. It has very little backlash, but the high ratio makes a joint harder to back-drive.
Peak torque
The torque a motor can produce briefly before heat limits it.
Continuous torque
The torque a motor can hold steadily without overheating. It is lower than peak torque, and it is what sustained work depends on.
Thermal derating
Lowering the allowed torque as the motor heats up, to protect it.
Field-oriented control
A way of controlling motor current so that torque and magnetic flux can be set separately. It is the usual method for joint motors.
Encoder
A sensor that measures angle. An incremental encoder counts movement; an absolute encoder reports the angle as soon as it powers up.
Slip ring
A rotating electrical contact that carries power or signals across a joint that turns continuously.
CAN and CAN FD
Controller area network, a common shared bus for joint drives. CAN FD is a newer version that carries larger messages at higher speed.
Proprioceptive actuator
An actuator that senses the forces on it through its own motor current, without a separate force sensor. Low reflected inertia and low friction make this possible (Wensing et al., 2017).
Impact mitigation factor
A measure, set out by Wensing et al., 2017, of how well a leg's actuators isolate the robot's body from the impact when the foot strikes the ground. Low reflected inertia improves it.
Torque density
Torque per unit of motor mass or volume. Higher torque density lets a joint use a lower gear ratio for the same output torque.
Duty cycle
The pattern of load and rest a motor works through over time. A continuous torque figure means little without a stated duty cycle.
Cogging and torque ripple
Cogging is a torque variation felt as the rotor turns, caused by magnetic attraction inside the motor even with no current. Torque ripple is the wider variation in torque during operation. Both show up as roughness at the joint.
Frameless motor
A motor supplied as a separate rotor and stator, without its own housing or bearings, to be built directly into a joint.
Fail-passive
Behaviour in which a fault leaves a machine in a safe, passive state, for example by removing power. For robots that must balance, removing power isn't safe, which leaves an open gap for certification (Ding et al., 2026).

Reading list

Field data, not ours; as of Nov 2026.

Open test method v0.1

When we have a motor to measure, we'll measure these quantities:

With every measurement we record these conditions:

Each result is reported with this template:

We wrote this method so anyone can use it on motors they already have. Comments on this method are welcome; see Contact.

We will post every result under this method, including poor ones.

What we'll publish, in order

  1. The test method.
  2. Our initial measured results, with their conditions.
  3. The raw data behind them.
  4. A description of the joint's telemetry.

No dates.

FAQ

Do you ship?

Not yet.

Do you publish specifications?

When we've measured them, with the test conditions stated.

Why a hollow centre?

The middle of a motor contributes relatively little torque, so leaving it open gives cables and sensor lines a shorter, protected path through the joint.

Is it certified?

Not yet certified. Certifying humanoids that must balance to stay upright is still an open question in the field; see Ding et al., 2026.

What happens to a balancing robot when power is cut?

Safety standards assume that removing power makes a machine safe, but a robot that must balance falls when power is cut. Certification for such robots is still an open question (Ding et al., 2026).

Why axial-flux?

Many joints are limited by their length along the axis, and axial-flux motors are short along the axis and wide. See Choosing a joint motor.

Why no specs yet?

We haven't measured them. We don't publish figures we haven't measured.

Will it fit my joint?

See the fit section on the Product page. Contact lists what to prepare.

Can I get a sample?

Not yet. We have no samples, and we don't take sample requests or reservations.

Will you publish results that disappoint?

Yes. We will post every result under our test method, including poor ones.